TRC 漏電ブレーカ

TRC 漏電ブレーカ
Tested by Recognized Third Party Safety Body.

CE Certified Portable Residual Current Device (PRCD);EU Directives 89/336/EEC - Electromagnetic Compatibility Directive,72/23/EEC - Low Voltage Equipment Directive & IEC 61540 - International standard for PRCD's. Available 120V - 230V,6mA - 30mA trip levels. Applications include:

  • Pressure Washers
  • rain Snakes
  • Floor Cleaners
  • Industrial Appliances
  • Power Tools
  • Pumps
  • Boat Lifts
  • Extension Cords
  • Construction Sites

To prevent unmonitored equipment startup,manual reset is required after PRCD trip and power outage.

FEATURES

Model 47000

  • Volts/Amps:120V/16A
  • Accepts:1.5 - 2.5mm2 conductor/7.8-16.2mm dia.Cord Setsl
  • Trip Level: 6 mA max.
  • CECompliant

Model 47010

  • Volts/Amps:230V/16A
  • Accepts:1.5 - 2.5mm2 conductor/7.8-16.2mm dia.Cord Sets
  • Trip Level: 10 mA max.
  • CECompliant

Model 47020

  • Volts/Amps:230V/16A
  • Accepts:1.5 - 2.5mm2 conductor/7.8-16.2mm dia.Cord Sets
  • Trip Level: 6 mA max.
  • CECompliant

Model 47030

  • Volts/Amps:230V/16A
  • Accepts:1.5 - 2.5mm2 conductor/7.8-16.2mm dia.Cord Sets
  • Trip Level: 30 mA max.
  • CECompliant

TECHNICAL DATA

Operating
Voltage Range
120/127 or 230V nominal @ 50/60 Hz
Operating
Load Current
16 amps max.
Residual Current
Trip Window
6,10,30mA
Response Time 40mS max at 5(IΔn)
Contacts Normally Open (Manual Reset)
Contacts open with loss of power
Environmental
Rating
IP-54

当ページに記載の製品についてのご質問・お問い合わせ・資料請求はこちらから

朝日技研工業株式会社へのお問い合わせ・ご相談・資料請求は下記より随時承っております。

お問い合わせフォームへ

TEL:045-474-3941(代)FAX:045-474-0250

このページのトップへ